GoodmanR-32

Goodman 2 Ton R32 Wall-Mount Air Handler With Built-in 8kW Heater (AWST24SU1308)

Model AWST24SU1308
Goodman 2 Ton R32 Wall-Mount Air Handler With Built-in 8kW Heater (AWST24SU1308)
Complete system
Complete system
✓ In stock, ships nationwide
Price
$993.00
Your total$993.00
Add to cart for an even lower price. Manufacturer pricing rules limit what we can show here, so your final discounted total appears in the AC Direct cart, with no obligation.

Check current price on AC Direct →

Free shippingTo your door
Price PromiseAC Direct
25 yearsHVAC expertise

Need it installed? We will connect you with a local HVAC contractor who can quote and install this system.Find a Contractor →

Key features

  • 2-ton wall-mount air handler configuration for ductless single-zone applications
  • Built-in 8 kW electric resistance heater for supplemental or primary heat
  • R-32 refrigerant with lower global warming potential than R-410A
  • Wall-mount cabinet design suited to rooms without ceiling or floor space for other configurations
  • Compatible with Goodman and select matched outdoor condensing or heat-pump units
  • Factory-installed heater eliminates a separate electric strip-heat add-on purchase

About this system

The Goodman AWST24SU1308 is a 2-ton wall-mount air handler designed for ductless or mini-split applications where a ceiling cassette or floor console does not fit the space. The built-in 8 kW electric heater means this unit can deliver both cooling and supplemental or primary heat from a single wall-mounted cabinet, making it a practical choice for additions, converted garages, sunrooms, or any room that lacks existing ductwork. It uses R-32 refrigerant, a lower global-warming-potential option that is becoming the standard replacement for R-410A across the industry.

Because no SEER2 rating is published for this specific model, efficiency comparisons are difficult to make with precision. Buyers should request the full performance data sheet from their contractor and confirm the outdoor unit pairing before purchase, since efficiency in a split system is always a matched-pair number. The 8 kW electric resistance heater is convenient but costs more to operate than a heat pump, so in climates with cold winters, understanding when the heater will run and at what electricity rate matters for long-term operating costs. This unit suits homeowners who want an affordable, all-in-one solution for a single zone and are comfortable with the trade-offs of a value-tier brand.

The HVAC.best Review
Reviewed by Dave Watson, HVAC.best
Score 2.9/5

The AWST24SU1308 is a straightforward value-tier wall-mount air handler with an integrated heater, priced well below comparable units from Carrier, Trane, or Mitsubishi. It is a reasonable choice for budget-conscious buyers who understand that long-term reliability will depend heavily on installation quality and that repair costs can climb after year seven. Without a published SEER2 figure, efficiency-focused buyers should verify performance data with their contractor before committing.

Efficiency2.5
Value3.5
Reliability2.5
Warranty3.0
Install-friendliness3.0

Overall score is the average of the five ratings above.

What we like

  • Purchase price runs 15 to 25 percent below comparable Carrier, Trane, and Lennox equipment
  • Built-in 8 kW heater simplifies installation by eliminating a separate electric heat kit
  • R-32 refrigerant is lower-GWP and is the direction the industry is heading
  • Wall-mount form factor works well in spaces where ceiling or floor units are not practical
  • Parts and service networks are widely available given Goodman's broad U.S. market presence

Trade-offs

  • No published SEER2 rating makes it hard to compare operating efficiency to competing models
  • Dual-run capacitors are the most commonly reported failure point across Goodman equipment, typically needing replacement around years 5 to 8
  • Evaporator coil leaks appear in a meaningful share of owner reviews, a potential mid-life cost
  • Electric resistance heat is less efficient than a heat pump, which raises operating costs in colder climates
Best for: Homeowners adding a single zone to a room addition, garage conversion, or sunroom who need both cooling and backup heat and are working within a tight budget. Look elsewhere if If long-term reliability and energy efficiency are the top priorities, or if the space will see heavy daily use year-round, consider Mitsubishi, Daikin, or Fujitsu wall-mount systems, which carry stronger reliability records and published efficiency ratings.

What homeowners and pros say about Goodman

Homeowners who choose Goodman equipment most often point to upfront affordability as the deciding factor, and that pattern holds for wall-mount air handlers like the AWST24SU1308. On Google dealer review pages, Goodman systems average around 3.8 out of 5 stars across hundreds of reviews per location, with cost savings cited repeatedly as the main reason buyers chose the brand. The picture on ConsumerAffairs is less favorable, sitting around 2.5 out of 5, though that platform skews toward frustrated owners rather than satisfied ones. The recurring theme there is repair costs that begin to accumulate after roughly year seven, which lines up with the documented pattern of dual-run capacitor failures and, in some cases, evaporator coil leaks that surface in mid-life ownership.

HVAC technicians tend to have a more nuanced view of Goodman. Most will install it without hesitation at the right price point, but they are consistent in saying that installation quality is the single largest variable in how long any Goodman unit lasts. Early refrigerant leaks, which a minority of owners report within the first year, are typically traced back to charge or connection issues at installation rather than factory defects. Compressor longevity is a real consideration: Goodman compressors tend to average 10 to 14 years in the field, versus 15 to 20 years on premium-brand equipment, so buyers planning to stay in a home long-term should factor a potential compressor replacement into their total cost of ownership. For a single-zone addition where budget matters and a qualified installer is doing the work, the AWST24SU1308 can deliver solid value; for heavily used primary living spaces, the case for spending more on a Mitsubishi or Daikin becomes easier to make.

Sources: ConsumerAffairs Goodman owner reviews, AHRI Directory of Certified Product Performance, U.S. DOE appliance and equipment efficiency standards, Goodman product specification sheets.

How it compares

Brand Comparable model SEER2 Stage Price position
Goodman AWST24SU1308 Not published Single-stage Value pick
Mitsubishi MSZ-GL Series (wall-mount) Up to 19.0 SEER2 depending on configuration Variable-speed inverter Considerably higher than Goodman
Daikin LV Series wall-mount air handler Up to 18.0 SEER2 depending on matched unit Variable-speed inverter Moderately to considerably higher than Goodman
Fujitsu ASWG Series wall-mount Up to 19.0 SEER2 depending on configuration Variable-speed inverter Moderately higher than Goodman

Competitor rows are comparable single-stage units at similar efficiency; price is relative position, not a quote.

Questions about this system

What outdoor unit does the AWST24SU1308 pair with?

Goodman specifies matched outdoor condensing or heat-pump units for this air handler, and the system efficiency and warranty depend on using an approved pairing. Ask your contractor to confirm the matched outdoor unit before purchasing, and request the combined AHRI or manufacturer performance data so you know the actual efficiency rating of the system as installed.

Can the built-in 8 kW heater serve as the primary heat source, or is it only supplemental?

The 8 kW electric resistance heater can function as primary heat in mild climates or well-insulated smaller spaces, but it operates at a straight 1-to-1 efficiency ratio, meaning it is significantly more expensive to run than a heat pump in colder weather. In climates where temperatures regularly drop below 35 to 40 degrees Fahrenheit, it is worth evaluating a heat-pump outdoor unit so the heater acts as backup rather than the main source.

What are the most common repairs I should budget for over the life of this unit?

Across Goodman equipment broadly, dual-run capacitor failure is the most frequently reported issue and typically runs 300 to 600 dollars to fix. Evaporator coil leaks show up in a meaningful share of long-term owner reviews and are more expensive to address. Compressor lifespan on Goodman units tends to average 10 to 14 years, compared to 15 to 20 years on premium brands, so budgeting for a potential compressor replacement in that window is prudent.

Is R-32 refrigerant harder to service than R-410A?

R-32 requires technicians to use equipment and practices rated for A2L mildly flammable refrigerants, so not every HVAC technician in every market is set up for it yet. Before purchasing, confirm that your local service providers are already working with R-32 systems, since availability of qualified service will affect both repair turnaround and cost.

What does the Goodman warranty cover on this model, and are there conditions I need to meet?

Goodman typically offers a 10-year parts warranty when the unit is registered online within a specified window after installation, with a shorter default coverage period if registration is missed. The warranty generally does not cover labor costs, which can be substantial, and it requires installation by a licensed HVAC contractor. Review the warranty document specific to this model and confirm registration requirements with your installer before the job is complete.

Specifications

Cooling capacity 2 Ton
Refrigerant R-32
Model AWST24SU1308
Image, specs, price and configurable options read from the AC Direct product page