Goodman 1.5 Ton 14 SEER2 60000 BTU 80% Two-Stage Gas Furnace With R32 Air Conditioner Condenser And Coil System – Upflow






Check current price on AC Direct →
Key features
- 1.5-ton cooling capacity with 14 SEER2 efficiency rating
- 60,000 BTU two-stage gas furnace at 80% AFUE
- R-32 refrigerant with lower global-warming potential than R-410A
- Upflow air handler configuration for basement or ground-level installs
- Two-stage heating reduces temperature swings on mild days
- Matched coil included, simplifying system sizing and warranty compliance
About this system
This Goodman upflow system pairs a 1.5-ton, 14 SEER2 air conditioner condenser with a 60,000 BTU, 80% AFUE two-stage gas furnace and an evaporator coil into a complete split system. The 14 SEER2 rating sits right at the federal minimum threshold for most U.S. climate zones, meaning it is code-compliant but not notably efficient. The two-stage furnace is a genuine comfort advantage over single-stage alternatives: it runs on a lower firing rate during mild weather, which reduces temperature swings and can lower gas consumption compared to a unit that only knows full blast or off. At 1.5 tons and 60,000 BTU, this system is sized for smaller homes, typically in the 600 to 900 square foot range depending on insulation, climate, and ceiling height.
The condenser uses R-32 refrigerant, a lower global-warming-potential alternative to the R-410A that dominated residential equipment for decades. R-32 systems are increasingly common, and while the refrigerant itself is mildly flammable, it is handled safely at residential scale and is well understood by most licensed HVAC technicians today. The upflow configuration means the air handler draws return air from the bottom and discharges conditioned air upward, the standard setup for basement or ground-level mechanical closet installations. Goodman prices this bundle roughly 15 to 25 percent below comparable Trane, Lennox, and Carrier configurations, which is its defining value proposition and its most meaningful trade-off in one.
This Goodman bundle is a straightforward, budget-accessible entry point for smaller homes that need a full heating and cooling replacement without premium brand pricing. The two-stage furnace adds real everyday comfort value, but the 14 SEER2 efficiency is the regulatory floor, not a selling point, and long-term ownership costs depend heavily on installation quality and willingness to address the brand's documented weak points before they escalate.
Overall score is the average of the five ratings above.
What we like
- Price sits 15 to 25 percent below comparable Trane, Lennox, and Carrier systems
- Two-stage furnace operation improves comfort and can reduce gas usage versus single-stage
- R-32 refrigerant is environmentally preferable to outgoing R-410A
- Matched coil included eliminates guesswork and protects manufacturer warranty
- Widely stocked parts and large installer network keep service accessible
Trade-offs
- 14 SEER2 is the minimum legal threshold, so utility savings versus higher-efficiency alternatives are real over a 10-plus year lifespan
- Dual-run capacitors are the most frequently reported failure, typically occurring mid-life and costing $300 to $600 per incident
- Evaporator coil leaks appear in a meaningful share of owner reviews and can be costly to diagnose and repair
- Compressor lifespan averages 10 to 14 years, shorter than the 15 to 20 years typically seen with premium brands
What homeowners and pros say about Goodman
Homeowners who chose Goodman equipment most often point to upfront affordability as the deciding factor, and that lines up with the brand’s documented pricing position of 15 to 25 percent below Trane, Lennox, and Carrier. On Google dealer reviews, Goodman systems average around 3.8 out of 5 across hundreds of reviews per location, with affordability and parts availability cited most often as strengths. The picture on ConsumerAffairs is rougher, averaging about 2.5 out of 5, though that platform skews toward owners who experienced problems rather than satisfied ones. The recurring theme there is repair costs climbing after roughly year seven, which aligns with the brand’s documented failure points: dual-run capacitors are the most commonly reported component failure and usually run $300 to $600 to fix, while evaporator coil leaks show up frequently enough in owner accounts to warrant attention.
HVAC technicians tend to describe Goodman as equipment where the install is everything. A well-commissioned system on a properly sized load calculation with a secure refrigerant charge tends to run without drama for a decade or more. One documented concern worth noting for this specific R-32 system: a minority of owners across Goodman’s product range report refrigerant leaks within the first year, and technicians typically attribute those to installation or initial charge issues rather than factory defects. Compressor longevity also runs shorter on average, roughly 10 to 14 years versus the 15 to 20 years more commonly associated with premium brands. For buyers prioritizing budget over longevity, Goodman delivers on its promise; for buyers expecting a set-it-and-forget-it system, the trade-offs are real and should factor into the total cost of ownership calculation.
Sources: ConsumerAffairs Goodman owner reviews, AHRI Directory of Certified Product Performance, U.S. DOE appliance and equipment efficiency standards, Goodman product specification sheets.
What it costs to run
At 14 SEER2, cooling this 1.5-ton system for a typical 1200-hour cooling season at the U.S. average electricity rate of $0.17/kWh works out to roughly $262 per year in cooling, about $12 less per year than a minimum-efficiency 13.4 SEER2 unit of the same size. Your real cost depends on your climate and local rate.
Method: (18,000 BTU/hr ÷ 14 SEER2) × 1200 hours ÷ 1000 × $0.17/kWh. Rate source: U.S. EIA average; cooling hours: moderate-climate estimate.
How it compares
| Brand | Comparable model | SEER2 | Stage | Price position |
|---|---|---|---|---|
| Goodman | 1.5T 14 SEER2 / 60K BTU 80% Two-Stage Bundle (this system) | 14 | Two-stage furnace / single-stage cooling | Value pick |
| Carrier | Performance 14 Series (24ACC4) | 14 | Single-stage | Roughly 15 to 25 percent more than this Goodman bundle |
| Trane | XR14 Series | 14 | Single-stage | Typically priced above this Goodman system at the entry tier |
| Lennox | Merit ML14XC1 | 14 | Single-stage | Positioned above Goodman at a comparable efficiency level |
Competitor rows are comparable single-stage units at similar efficiency; price is relative position, not a quote.
Questions about this system
Is 1.5 tons enough for my home?
A proper Manual J load calculation is the only reliable answer, but as a rough guide, 1.5 tons typically suits well-insulated homes in the 600 to 900 square foot range in moderate climates. Oversizing is a common mistake that causes short cycling, humidity problems, and premature wear, so have your installer run the numbers before committing.
How does the R-32 refrigerant affect service and safety?
R-32 is mildly flammable but is handled safely at residential scale and requires no special equipment beyond what a certified HVAC technician already carries. Most technicians are familiar with it, though you should confirm your service provider is comfortable working with R-32 systems before scheduling any refrigerant work.
What does two-stage heating actually mean for day-to-day comfort?
The furnace fires at a lower output level during mild weather and ramps up only when outdoor temperatures drop significantly. This means longer, gentler heating cycles with fewer sharp temperature swings and less on-off cycling noise compared to a single-stage furnace.
What are the most common repair issues I should budget for with Goodman equipment?
Dual-run capacitor failures are the most frequently reported problem and are typically a straightforward $300 to $600 fix. Evaporator coil leaks show up in a meaningful share of owner reviews and are more expensive to address. Early refrigerant leaks within the first year are usually tied to installation or initial charge issues rather than the equipment itself.
What warranty comes with this system and does it require registration?
Goodman typically offers a 10-year parts limited warranty on registered systems, but the specific terms depend on the model number and whether you register within the required window after installation. Failure to register usually drops coverage to a shorter base period, so confirm registration requirements with your installer at the time of commissioning.
Specifications
| Cooling capacity | 1.5 Ton |
| Efficiency | 14 SEER2 |
| Furnace output | 60000 BTU |
| Configuration | Upflow |
| Refrigerant | R-32 |