GoodmanR-32

Goodman 2 Ton 15.2 SEER2 R32 Heat Pump Condenser (GLZS4BA2410)

Model GLZS4BA2410
Goodman 2 Ton 15.2 SEER2 R32 Heat Pump Condenser (GLZS4BA2410)
Complete system
Complete system
✓ In stock, ships nationwide
Price
$2,302.00
Your total$2,302.00
Add to cart for an even lower price. Manufacturer pricing rules limit what we can show here, so your final discounted total appears in the AC Direct cart, with no obligation.

Check current price on AC Direct →

Free shippingTo your door
Price PromiseAC Direct
25 yearsHVAC expertise

Need it installed? We will connect you with a local HVAC contractor who can quote and install this system.Find a Contractor →

Key features

  • 2-ton capacity suited to smaller conditioned spaces
  • 15.2 SEER2 efficiency rating meets current federal minimums
  • R-32 refrigerant with lower global warming potential than R-410A
  • Single-stage scroll compressor with straightforward operation
  • Requires matched evaporator coil or air handler to complete system
  • 10-year parts warranty when registered within 60 days of install

About this system

The Goodman GLZS4BA2410 is a 2-ton, 15.2 SEER2 heat pump condenser designed for smaller homes and well-insulated spaces in the 600 to 900 square foot range, depending on climate and insulation. It runs on R-32 refrigerant, a lower-global-warming-potential alternative to the older R-410A, which puts it on the right side of evolving EPA regulations and positions owners to avoid the supply and cost headaches that are already building around R-410A service. Single-stage operation means the compressor is either fully on or fully off, a straightforward design that keeps upfront costs down but delivers less precise humidity control and comfort consistency than two-stage or variable-speed alternatives.

At 15.2 SEER2, this unit clears the federal minimum efficiency threshold by a modest margin. It is not a high-efficiency product, but it is a compliant, functional one that will reduce operating costs compared to an aging 10 to 13 SEER system. The R-32 refrigerant charge runs at lower pressure than R-410A, which can simplify leak diagnostics and reduce refrigerant costs over the life of the system. This condenser requires a matched air handler or evaporator coil to complete the system, and as with all Goodman equipment, the quality of the installation will have an outsized impact on how long it performs reliably.

The HVAC.best Review
Reviewed by Dave Watson, HVAC.best
Score 3.2/5

The GLZS4BA2410 is a budget-accessible heat pump that delivers baseline efficiency and straightforward operation at a price point well below Carrier, Trane, or Lennox equivalents. The R-32 refrigerant is a genuine forward-looking feature, but single-stage operation and Goodman's documented mid-life repair rate mean buyers are making a real trade-off between upfront savings and long-term cost of ownership. It suits homeowners who are budget-constrained, plan to stay in the home 8 to 10 years, and have a reliable installer.

Efficiency3.0
Value4.0
Reliability2.5
Warranty3.5
Install-friendliness3.0

Overall score is the average of the five ratings above.

What we like

  • Priced 15 to 25 percent below comparable Carrier, Trane, and Lennox units
  • R-32 refrigerant reduces regulatory risk and long-term service costs
  • 10-year parts warranty (registered) is competitive for the value tier
  • Simple single-stage design means fewer electronic components to fail
  • Widely stocked by distributors, keeping parts availability reasonable

Trade-offs

  • Single-stage operation provides less precise humidity and comfort control than two-stage or variable-speed alternatives
  • Compressor lifespan averages 10 to 14 years versus 15 to 20 for premium brands
  • Dual-run capacitors are a documented frequent failure point, typically after year 5 to 7
  • A minority of owners have reported refrigerant leaks in the first year, usually traceable to installation quality rather than the unit itself
Best for: Budget-conscious homeowners replacing an aging system who have access to a skilled installer and realistic expectations about mid-life maintenance costs. Look elsewhere if If you plan to stay in the home 15 or more years, prioritize comfort consistency, or are in a high-humidity climate where humidity control matters, a two-stage or variable-speed unit from Carrier, Trane, or Lennox warrants the higher upfront cost.

What homeowners and pros say about Goodman

Homeowners who have priced out HVAC replacements tend to land on Goodman when the gap between its sticker price and a Carrier or Trane quote feels too wide to ignore. On Google dealer reviews, Goodman systems average around 3.8 out of 5, and the most consistent praise is straightforward: the price makes the decision easier. On ConsumerAffairs, the score drops to roughly 2.5 out of 5, a channel that skews toward people who have had problems, and the recurring story there involves repair bills starting to pile up somewhere after year 7. That pattern is consistent with the documented failure modes for this brand: dual-run capacitors tend to go first, usually a 300 to 600 dollar fix if caught early, followed in some cases by evaporator coil leaks and, over the longer term, compressors that average 10 to 14 years rather than the 15 to 20 years more commonly reported for premium brands.

HVAC technicians are generally candid about Goodman: the equipment is adequate, but they will tell you the install matters more than the nameplate. First-year refrigerant leaks, which a minority of owners report, are almost always traced back to improper charging at installation rather than anything that left the factory wrong. For the GLZS4BA2410 specifically, the R-32 refrigerant is a practical upgrade that pros tend to view positively, since it simplifies leak detection and carries lower long-term regulatory risk than R-410A. The honest summary from the field is that a well-installed Goodman in a moderate climate, maintained on schedule, will do the job. The risk is that cutting corners on the installer to match the savings on the equipment tends to erase those savings fairly quickly.

Sources: ConsumerAffairs Goodman owner reviews, AHRI Directory of Certified Product Performance, U.S. DOE appliance and equipment efficiency standards, Goodman product specification sheets.

What it costs to run

At 15.2 SEER2, cooling this 2-ton system for a typical 1200-hour cooling season at the U.S. average electricity rate of $0.17/kWh works out to roughly $322 per year in cooling, about $43 less per year than a minimum-efficiency 13.4 SEER2 unit of the same size. Your real cost depends on your climate and local rate.

Method: (24,000 BTU/hr ÷ 15.2 SEER2) × 1200 hours ÷ 1000 × $0.17/kWh. Rate source: U.S. EIA average; cooling hours: moderate-climate estimate.

How it compares

Brand Comparable model SEER2 Stage Price position
Goodman GLZS4BA2410 15.2 Single-stage Value pick
Carrier Comfort 15 (25HCE4) 15.2 Single-stage 15 to 25 percent higher than Goodman
Trane XR15 (4TWR5) 15.0–16.0 Single-stage 20 to 30 percent higher than Goodman
Lennox Merit ML15XP1 15.0–15.5 Single-stage 20 to 30 percent higher than Goodman

Competitor rows are comparable single-stage units at similar efficiency; price is relative position, not a quote.

Questions about this system

Does the GLZS4BA2410 work as a standalone unit or do I need to buy additional components?

This is a condenser only. You will need a compatible indoor air handler or evaporator coil, refrigerant line set, and electrical disconnect to complete the system. Goodman recommends using a matched indoor unit to qualify for full warranty coverage and rated efficiency.

Why does this unit use R-32 instead of R-410A, and does that affect service costs?

R-32 has a lower global warming potential than R-410A and is increasingly the industry standard for new equipment as EPA regulations tighten. R-32 is less expensive per pound than R-410A currently, and technicians familiar with it are becoming more common, though not every older HVAC contractor has updated their equipment to handle it yet. Confirm your installer is R-32 certified before scheduling.

What is the most common repair I should budget for over the first 10 years?

Based on documented owner experience with Goodman heat pumps, dual-run capacitor failure is the most frequently reported issue, typically occurring after year 5 to 7. This is generally a low-severity repair in the 300 to 600 dollar range when handled promptly. Evaporator coil leaks are a secondary concern worth discussing with your installer.

How important is the installer for a unit like this?

Critically important. Technicians consistently note that Goodman's real-world performance and longevity hinge more on installation quality than on almost any other factor. A minority of first-year refrigerant leaks reported by owners are typically attributed to improper charging at install rather than manufacturing defects. Choosing a licensed, experienced installer is arguably more important than the brand choice itself.

Does the 10-year parts warranty require registration, and what does it actually cover?

Yes, the 10-year parts warranty requires product registration within 60 days of installation. Without registration, coverage defaults to 5 years on parts. The warranty covers parts but not labor, refrigerant, or diagnostic fees, so actual out-of-pocket repair costs during the warranty period can still be significant depending on your service agreement.

Specifications

Cooling capacity 2 Ton
Efficiency 15.2 SEER2
Refrigerant R-32
Model GLZS4BA2410
Image, specs, price and configurable options read from the AC Direct product page