GoodmanR-32

Goodman 2 Ton AC And 80000 BTU 80% AFUE Gas Furnace System | 16 SEER2 AC | Multi-Speed ECM Low NOx Furnace | Upflow | R32

80000 BTU • 80% AFUE • Upflow
Goodman 2 Ton AC And 80000 BTU 80% AFUE Gas Furnace System | 16 SEER2 AC | Multi-Speed ECM Low NOx Furnace | Upflow | R32
Complete system
Complete system
Condenser
Condenser
Gas furnace
Gas furnace
Evaporator coil
Evaporator coil
✓ In stock, ships nationwide
Price
$4,494.00
Your total$4,494.00
Add to cart for an even lower price. Manufacturer pricing rules limit what we can show here, so your final discounted total appears in the AC Direct cart, with no obligation.

Check current price on AC Direct →

Free shippingTo your door
Price PromiseAC Direct
25 yearsHVAC expertise

Need it installed? We will connect you with a local HVAC contractor who can quote and install this system.Find a Contractor →

Key features

  • 16 SEER2 rated central air conditioner, meeting current federal efficiency minimums
  • 80,000 BTU output gas furnace with 80% AFUE single-stage heating
  • Multi-speed ECM blower motor for quieter operation and improved humidity control
  • R-32 refrigerant with lower global warming potential than R-410A
  • Upflow configuration designed for basement or ground-level utility closet installs
  • 2-ton cooling capacity sized for smaller to mid-size residential applications

About this system

The Goodman 2-ton, 16 SEER2 air conditioner paired with an 80,000 BTU, 80% AFUE upflow gas furnace is a straightforward, budget-conscious comfort system aimed at homeowners replacing aging equipment in smaller to mid-size homes, typically 900 to 1,400 square feet depending on climate and insulation. The 16 SEER2 rating sits at the lower edge of the current efficiency tier but meets federal minimums in most regions and will deliver a noticeable improvement over anything rated below 14 SEER. The R-32 refrigerant is a genuine upgrade over legacy R-410A, carrying a lower global warming potential and requiring a smaller charge volume, which is better for the environment and can reduce refrigerant costs if a top-off is ever needed.

The gas furnace side uses an 80% AFUE rating, meaning one-fifth of every fuel dollar escapes as exhaust. That is an honest trade-off: you pay less upfront than you would for a 96% AFUE condensing unit, but you will spend modestly more on gas each winter. The multi-speed ECM blower motor is a meaningful inclusion at this price point, running at lower speeds during mild conditions to improve humidity control, reduce noise, and trim electricity use compared to a single-speed PSC motor. The upflow configuration suits homes where the furnace sits in a basement or utility closet with ductwork running above it, which covers the majority of northern-climate installations.

This system is sold as an equipment package and will require a licensed HVAC technician for installation, refrigerant charging, and commissioning. Because Goodman’s real-world performance tracks closely with installation quality, selecting an experienced installer matters as much as the equipment itself. Homeowners in mild climates or those with a modest budget who want a dependable, code-compliant system without premium brand pricing will find this combination a reasonable starting point.

The HVAC.best Review
Reviewed by Dave Watson, HVAC.best
Score 3.3/5

This Goodman package delivers a functional, code-compliant heating and cooling system at a price point meaningfully below comparable Carrier, Trane, and Lennox offerings. The ECM blower and R-32 refrigerant are genuine value-adds at this tier, but the 80% AFUE furnace and single-stage cooling mean higher long-term operating costs than mid-efficiency alternatives. Owners who invest in a quality installation and handle minor maintenance proactively can get solid years of service; those who cut corners on the install or ignore early warning signs are the ones behind the brand's lower consumer ratings.

Efficiency3.0
Value4.0
Reliability2.5
Warranty3.5
Install-friendliness3.5

Overall score is the average of the five ratings above.

What we like

  • Priced roughly 15 to 25 percent below comparable Carrier, Trane, and Lennox systems, freeing budget for a quality install
  • Multi-speed ECM blower motor improves comfort and humidity management compared to basic PSC blowers at this price
  • R-32 refrigerant has a lower environmental impact and typically costs less per pound than R-410A if service is needed
  • Upflow design is a proven, widely understood configuration that most technicians can service without specialty knowledge
  • Dual-run capacitor failures, the most common reported issue, are a relatively inexpensive fix in the $300 to $600 range

Trade-offs

  • 80% AFUE efficiency means ongoing higher fuel costs compared to 95%+ condensing furnaces, adding up over many heating seasons
  • Compressor lifespan averages 10 to 14 years versus 15 to 20 years typical of premium brands, meaning earlier potential replacement
  • Evaporator coil leaks appear in a notable share of owner feedback, and a minority of owners report refrigerant leaks within the first year
  • ConsumerAffairs reviews average around 2.5 out of 5, with repair costs climbing after roughly year 7 as a recurring complaint
Best for: Budget-conscious homeowners replacing a failed system who want a code-compliant, functional package and plan to pair it with an experienced local installer. Look elsewhere if If you are in a colder climate where heating bills are a major concern, or if you want compressor longevity closer to 15 to 20 years, a two-stage or variable-speed system from Carrier, Trane, or Lennox with a 96% AFUE furnace will cost more upfront but return more over a longer service life.

What homeowners and pros say about Goodman

Homeowners who have lived with Goodman equipment for several years tend to split into two camps. Those who had a careful, experienced installer and kept up with seasonal maintenance often describe reliable operation and appreciate the lower upfront cost. Those who ran into problems point to the brand’s ConsumerAffairs score of around 2.5 out of 5 as reflective of their experience, with the recurring theme being repair bills that start to accumulate after roughly year seven. The specific failure modes that show up most often in owner accounts are dual-run capacitor failures on the AC side, evaporator coil leaks, and, in a smaller portion of cases, refrigerant leaks within the first year that typically trace back to the install rather than the equipment itself.

HVAC technicians tend to be pragmatic about Goodman. Dealer Google reviews across many locations average around 3.8 out of 5, and affordability is the most consistent praise. Pros who work on these systems regularly note that the parts are widely available and the dual-run capacitor, while a common failure, is one of the easier and cheaper fixes in residential HVAC. The compressor lifespan concern is more serious: Goodman compressors tend to average 10 to 14 years compared to 15 to 20 years in premium brands, which means a full system replacement may come sooner. For this specific package, the ECM blower motor and R-32 refrigerant are features that technicians view positively at this price tier, but most will emphasize that a clean, properly charged install is what separates a Goodman that lasts from one that does not.

Sources: ConsumerAffairs Goodman owner reviews, AHRI Directory of Certified Product Performance, U.S. DOE appliance and equipment efficiency standards, Goodman product specification sheets.

What it costs to run

At 16 SEER2, cooling this 2-ton system for a typical 1200-hour cooling season at the U.S. average electricity rate of $0.17/kWh works out to roughly $306 per year in cooling, about $59 less per year than a minimum-efficiency 13.4 SEER2 unit of the same size. Your real cost depends on your climate and local rate.

Method: (24,000 BTU/hr ÷ 16 SEER2) × 1200 hours ÷ 1000 × $0.17/kWh. Rate source: U.S. EIA average; cooling hours: moderate-climate estimate.

How it compares

Brand Comparable model SEER2 Stage Price position
Goodman GLXS3BA24 / GMVC8 series (this system) 16 Single-stage Value pick
Carrier Comfort 16 series (24ACC636) 16 Single-stage Typically 15 to 25 percent more than this Goodman package
Trane XR16 series 16 Single-stage Typically 15 to 25 percent more than this Goodman package
Lennox Merit 16ACX series 16 Single-stage Typically 15 to 25 percent more than this Goodman package

Competitor rows are comparable single-stage units at similar efficiency; price is relative position, not a quote.

Questions about this system

Will a 2-ton system be enough to cool my 1,200 square foot home?

Two tons is a reasonable starting point for a well-insulated 1,200 square foot home in a moderate climate, but actual sizing depends on ceiling height, window area, insulation levels, and local design temperatures. A proper Manual J load calculation by your installer is the only reliable way to confirm the right tonnage before purchase.

Is 80% AFUE going to cost me significantly more in gas bills than a 96% furnace?

Over a full heating season, an 80% AFUE furnace wastes about 20 cents of every gas dollar, while a 96% unit wastes roughly 4 cents. In a cold climate where you run the heat heavily, that gap can add up to a meaningful annual difference. In a mild climate with short heating seasons, the payback period on a high-efficiency upgrade can stretch to 10 or more years.

What does the R-32 refrigerant mean for me as a homeowner?

R-32 is the newer refrigerant Goodman has moved to as the industry phases away from R-410A. For you practically, it means a technician will need R-32 certified equipment to service the system, but that certification is increasingly common. The environmental footprint is lower and per-pound costs tend to be competitive with R-410A.

What are the most likely repair costs I should plan for down the road?

Dual-run capacitor failure is the most commonly reported issue on Goodman AC units and typically runs $300 to $600 to repair, including the service call. Evaporator coil leaks are a documented concern in owner reviews and are more expensive to address. Budget for annual preventive maintenance to catch capacitor wear early and keep the coil clean.

Can any HVAC technician install this, or does it require a Goodman-authorized dealer?

Any licensed HVAC contractor can install Goodman equipment, and it does not require an authorized dealer for the standard install. However, to activate the full parts warranty you will generally need registration and, in many cases, installation by a licensed contractor, so confirm the warranty terms with Goodman directly before signing off on the paperwork.

Specifications

Cooling capacity 2 Ton
Efficiency 16 SEER2
Furnace output 80000 BTU
Furnace efficiency 80% AFUE
Configuration Upflow
Refrigerant R-32
Image, specs, price and configurable options read from the AC Direct product page