GoodmanR-32

Goodman 3 Ton Package Unit Heat Pump & AC | 13.4 SEER2 Horizontal Discharge | R32

Horizontal
Goodman 3 Ton Package Unit Heat Pump & AC | 13.4 SEER2 Horizontal Discharge | R32
Complete system
Complete system
Condenser
Condenser
Gas furnace
Gas furnace
Evaporator coil
Evaporator coil
✓ In stock, ships nationwide
Price
$5,026.00
Your total$5,026.00
Add to cart for an even lower price. Manufacturer pricing rules limit what we can show here, so your final discounted total appears in the AC Direct cart, with no obligation.

Check current price on AC Direct →

Free shippingTo your door
Price PromiseAC Direct
25 yearsHVAC expertise

Need it installed? We will connect you with a local HVAC contractor who can quote and install this system.Find a Contractor →

Key features

  • 3-ton capacity, suitable for roughly 1,400 to 1,800 sq ft depending on climate and insulation
  • 13.4 SEER2 efficiency rating, meeting current federal minimum standards
  • Horizontal discharge configuration for rooftop or side-mount installations
  • R-32 refrigerant with lower global-warming potential than R-410A
  • All-in-one package unit integrates heat pump and cooling in a single outdoor cabinet
  • Goodman factory warranty covers parts for 10 years with registration (compressor included)

About this system

The Goodman 3-ton horizontal-discharge package unit combines a heat pump and air conditioner into a single cabinet designed to mount along the side of a building or on a rooftop curb, making it a practical choice for homes without a basement or interior mechanical room, manufactured housing, and light commercial applications where space is tight. At 13.4 SEER2, it meets the current federal minimum efficiency standard for most U.S. climate zones and will cut energy use compared to an aging R-22 or low-SEER system, though it sits at the entry level of today’s efficiency range rather than near the top of it.

This unit runs on R-32 refrigerant, a lower global-warming-potential option that is increasingly common as the industry moves away from R-410A. R-32 systems require technicians who are familiar with its slightly higher operating pressures, so confirming your installer has experience with R-32 before booking is worth the extra phone call. The horizontal discharge configuration also means airflow direction and duct connection placement are fixed, so verifying that the existing duct layout matches before purchase will save significant cost and frustration on installation day.

The HVAC.best Review
Reviewed by Dave Watson, HVAC.best
Score 3.2/5

This Goodman package unit delivers solid entry-level efficiency in a configuration that suits a specific set of installation scenarios well, and its price point makes it genuinely accessible. The trade-off is a brand track record that shows shorter average compressor life and more repair activity after year 7 than premium competitors, meaning the upfront savings can narrow over a 15-year ownership horizon.

Efficiency3.0
Value4.0
Reliability2.5
Warranty3.5
Install-friendliness3.0

Overall score is the average of the five ratings above.

What we like

  • Priced 15 to 25 percent below comparable Trane, Carrier, and Lennox package units
  • R-32 refrigerant is a forward-looking choice with lower environmental impact
  • 10-year parts warranty with registration covers the compressor and functional components
  • Single-cabinet design simplifies rooftop and manufactured-home installations
  • Broad dealer and parts network makes service scheduling and repair sourcing relatively easy

Trade-offs

  • Dual-run capacitors are the most frequently reported failure component, typically needing replacement between year 3 and year 7
  • Compressor lifespan averages 10 to 14 years versus 15 to 20 years for premium-brand compressors
  • A minority of owners report refrigerant leaks within the first year, most traced to installation or charge issues rather than the unit itself
  • Evaporator coil leaks appear in a meaningful share of owner reviews, which can be a costly mid-life repair
Best for: Homeowners or property managers replacing an aging package unit on a budget who want a straightforward, code-compliant system and plan to stay in the property for 8 to 12 years. Look elsewhere if If you expect to own the home for 15-plus years or have had repeated HVAC repair costs in the past, the lower failure rates and longer compressor life of Trane or Carrier package units are likely worth the higher upfront cost.

What homeowners and pros say about Goodman

Homeowners who chose this Goodman package unit most often point to its lower purchase price as the deciding factor, and that sentiment is reflected in Google dealer review averages that land around 3.8 out of 5, where affordability and straightforward installation tend to draw the most positive comments. The ConsumerAffairs score is considerably lower, sitting around 2.5 out of 5, though that platform attracts a disproportionate share of complaints, and the recurring theme there is repair costs climbing after roughly year 7 rather than immediate dissatisfaction.

HVAC technicians who work on Goodman package units regularly note that installation quality is the single biggest variable in how long one lasts. The documented weak points in the field are specific: dual-run capacitors are the most commonly replaced component and usually a low-stakes repair when caught during routine maintenance, but evaporator coil leaks and compressor failures draw sharper criticism because of their cost. Compressors in Goodman equipment average 10 to 14 years in real-world reports, a meaningful gap compared to the 15 to 20 years more commonly seen in premium-brand units. A smaller group of owners reports refrigerant leaks within the first year, a pattern that technicians typically attribute to installation or charge errors rather than a manufacturing defect in the unit itself.

Sources: ConsumerAffairs Goodman owner reviews, AHRI Directory of Certified Product Performance, U.S. DOE appliance and equipment efficiency standards, Goodman product specification sheets.

What it costs to run

At 13.4 SEER2, cooling this 3-ton system for a typical 1200-hour cooling season at the U.S. average electricity rate of $0.17/kWh works out to roughly $548 per year in cooling, about $0 less per year than a minimum-efficiency 13.4 SEER2 unit of the same size. Your real cost depends on your climate and local rate.

Method: (36,000 BTU/hr ÷ 13.4 SEER2) × 1200 hours ÷ 1000 × $0.17/kWh. Rate source: U.S. EIA average; cooling hours: moderate-climate estimate.

How it compares

Brand Comparable model SEER2 Stage Price position
Goodman 3-Ton Horizontal Package Heat Pump (this unit) 13.4 Single-stage Value pick
Carrier WeatherMaster 50XC 14.0–16.0 Single-stage 15 to 25 percent above this Goodman
Trane Precedent YSC/YHC Series 13.4–15.0 Single-stage 15 to 25 percent above this Goodman
Lennox LRP14HP 14.0 Single-stage 20 to 30 percent above this Goodman

Competitor rows are comparable single-stage units at similar efficiency; price is relative position, not a quote.

Questions about this system

Can any HVAC technician install this unit, or does it require someone certified for R-32?

All EPA Section 608 certified technicians are legally permitted to work with R-32, but because R-32 operates at higher pressures than R-410A, you should confirm your installer has hands-on R-32 experience before the job starts. An improper charge is one of the documented causes of early refrigerant leaks on Goodman units.

Will 13.4 SEER2 qualify for any federal tax credits or utility rebates?

As of 2025, the federal energy efficiency tax credit under the Inflation Reduction Act requires a higher SEER2 threshold (typically 15.2 SEER2 or above for heat pumps in most regions), so this unit likely does not qualify. Check with your utility company separately, as some local rebate programs have lower thresholds.

How do I know if my existing ductwork is compatible with the horizontal discharge configuration?

Horizontal discharge units connect supply and return air through the bottom or side of the cabinet rather than the top, so your existing duct plenum must align with those openings. Have your installer compare the unit's connection dimensions to your current duct layout before you purchase, because adapting mismatched ductwork adds labor cost and can reduce system performance.

What does the Goodman capacitor failure issue actually mean for me as an owner?

Dual-run capacitors are the most commonly reported failure point on Goodman equipment and typically fail somewhere between year 3 and year 7. The good news is that it is usually a quick repair in the 300 to 600 dollar range when caught early, and it does not indicate broader system failure. Scheduling annual maintenance that includes a capacitor check can catch degrading capacitors before they fail and damage the compressor.

Is the 10-year warranty automatic, or do I have to do something to activate it?

The 10-year parts warranty requires product registration with Goodman, typically within 60 days of installation. Without registration, the warranty period drops to five years on parts in most cases. Keep your installation invoice and register the unit on Goodman's website as soon as the job is complete.

Specifications

Cooling capacity 3 Ton
Efficiency 13.4 SEER2
Configuration Horizontal
Refrigerant R-32
Image, specs, price and configurable options read from the AC Direct product page