GoodmanR-32

Goodman Furnace And AC – 1.5 Ton 15.2 SEER2 AC With 60000 BTU 96% AFUE Two Stage Multi-Speed ECM Gas Furnace System – Upflow | R32

60000 BTU • 96% AFUE • Upflow
Goodman Furnace And AC - 1.5 Ton 15.2 SEER2 AC With 60000 BTU 96% AFUE Two Stage Multi-Speed ECM Gas Furnace System - Upflow | R32
Complete system
Complete system
Condenser
Condenser
Gas furnace
Gas furnace
Evaporator coil
Evaporator coil
✓ In stock, ships nationwide
Price
$4,553.00
Your total$4,553.00
Add to cart for an even lower price. Manufacturer pricing rules limit what we can show here, so your final discounted total appears in the AC Direct cart, with no obligation.

Check current price on AC Direct →

Free shippingTo your door
Price PromiseAC Direct
25 yearsHVAC expertise

Need it installed? We will connect you with a local HVAC contractor who can quote and install this system.Find a Contractor →

Key features

  • 1.5-ton cooling capacity rated at 15.2 SEER2 for above-minimum efficiency
  • 60,000 BTU two-stage gas furnace at 96% AFUE for high-efficiency heating
  • Multi-speed ECM blower motor reduces electricity use and improves airflow control
  • R-32 refrigerant with lower global-warming potential than R-410A
  • Upflow configuration suits basement or closet installations with supply air exiting the top
  • Two-stage heat operation provides quieter, more consistent temperatures than single-stage units

About this system

This Goodman bundle pairs a 1.5-ton, 15.2 SEER2 air conditioner with a 60,000 BTU, 96% AFUE two-stage gas furnace in an upflow configuration, making it a logical fit for smaller homes, condos, or additions in the 600-to-900 square-foot range where heating loads are modest and cooling demand is light. The R-32 refrigerant charge is a forward-looking choice: R-32 has a lower global-warming potential than the R-410A it replaces and is increasingly the industry standard, so finding a qualified technician to service it will only get easier over time.

The two-stage furnace is the real standout here. Running at low fire the majority of the time, it cycles less aggressively than a single-stage unit, which translates to more even room temperatures, quieter operation, and reduced wear on the heat exchanger. The multi-speed ECM blower motor complements that by ramping airflow gradually rather than slamming on at full speed, cutting electricity use on the air-handler side and reducing the drafty blasts that single-speed systems are known for. At 96% AFUE, nearly all of the gas going in becomes usable heat, which matters most in climates with long heating seasons. The 15.2 SEER2 rating lands just above the federal minimum for most regions, so it is efficient without carrying the premium price of a high-SEER2 system.

This system suits budget-conscious homeowners who want meaningfully better comfort than an entry-level single-stage setup but cannot justify the cost of a variable-speed premium system. It rewards careful installation: Goodman’s real-world longevity is closely tied to how well the system is commissioned, so choosing an experienced, licensed installer matters as much as the equipment itself.

The HVAC.best Review
Reviewed by Dave Watson, HVAC.best
Score 3.2/5

This Goodman bundle delivers genuinely capable specs at a price most premium brands cannot match, and the two-stage furnace with ECM blower punches above its cost tier on comfort. The trade-off is a brand with a documented history of capacitor failures, evaporator coil leaks, and compressors that tend to age out sooner than premium alternatives, so buyers should budget for maintenance and lean hard on install quality.

Efficiency3.5
Value4.0
Reliability2.5
Warranty3.0
Install-friendliness3.0

Overall score is the average of the five ratings above.

What we like

  • Two-stage furnace with ECM blower provides noticeably more even heat and quieter operation than single-stage systems
  • 96% AFUE keeps gas consumption high and waste heat low, lowering monthly heating bills in cold climates
  • R-32 refrigerant is serviceable, increasingly common, and more environmentally sound than older refrigerants
  • Goodman pricing typically runs 15 to 25 percent below Trane, Carrier, and Lennox for comparable specifications
  • 15.2 SEER2 clears federal minimums by a reasonable margin without the steep cost of high-SEER2 equipment

Trade-offs

  • Dual-run capacitors are the most commonly reported failure point and, while inexpensive to fix, they add up after year 7
  • Evaporator coil leaks appear in a meaningful share of owner reviews, a concern for a refrigerant like R-32 that requires certified handling
  • Compressors average 10 to 14 years versus the 15 to 20 years more common in premium brands, shortening the expected equipment life cycle
  • A minority of owners report refrigerant leaks within the first year, most often traced to installation or initial charge problems rather than the unit itself
Best for: Homeowners in smaller homes or supplemental zones who want two-stage comfort and high furnace efficiency on a tight budget and plan to invest in a quality installation. Look elsewhere if If you expect to stay in the home 15 or more years and want the longest possible compressor life with fewer service calls, a premium brand like Trane, Carrier, or Lennox is worth the higher upfront cost.

What homeowners and pros say about Goodman

Homeowners who choose Goodman most often point to the price as the deciding factor, and the Google dealer review average of around 3.8 out of 5 reflects a base of buyers who feel they got reasonable performance for the money. The praise tends to center on systems that were installed carefully by experienced technicians, reinforcing what those same technicians say: Goodman equipment can perform reliably, but the installation is the single biggest variable in how long it lasts. Complaints on ConsumerAffairs, which skews toward owners who are already frustrated, pull the score down to around 2.5 out of 5, with the most common grievance being rising repair costs after roughly year seven.

On the specific failure modes, dual-run capacitor replacements are the issue HVAC technicians mention most often on Goodman systems. They are a low-cost, quick fix in the 300 to 600 dollar range, but they have a habit of recurring. Evaporator coil leaks are a more serious documented concern, particularly relevant here because R-32 refrigerant requires certified recovery and handling, making a coil replacement more involved than on older systems. Compressor longevity is another real consideration: Goodman compressors tend to average 10 to 14 years, noticeably shorter than the 15-to-20-year range more typical of Trane, Carrier, and Lennox. For a 1.5-ton system that is likely serving a smaller space, the lower upfront cost may offset those service realities for many buyers, especially those who plan to move within a decade or who are working with a tight budget.

Sources: ConsumerAffairs Goodman owner reviews, AHRI Directory of Certified Product Performance, U.S. DOE appliance and equipment efficiency standards, Goodman product specification sheets.

What it costs to run

At 15.2 SEER2, cooling this 1.5-ton system for a typical 1200-hour cooling season at the U.S. average electricity rate of $0.17/kWh works out to roughly $242 per year in cooling, about $32 less per year than a minimum-efficiency 13.4 SEER2 unit of the same size. Your real cost depends on your climate and local rate.

Method: (18,000 BTU/hr ÷ 15.2 SEER2) × 1200 hours ÷ 1000 × $0.17/kWh. Rate source: U.S. EIA average; cooling hours: moderate-climate estimate.

How it compares

Brand Comparable model SEER2 Stage Price position
Goodman 1.5T 15.2 SEER2 AC + 60k BTU 96% AFUE Two-Stage ECM Furnace (this system) 15.2 Two-stage furnace / single-stage AC Value pick
Carrier Performance 13 / 96% Two-Stage (58TP / 24ACC) series 15-16 Two-stage furnace / single-stage AC Typically 15 to 25 percent more than Goodman
Trane S9V2 Furnace / XR15 AC series 15-16 Two-stage furnace / single-stage AC Typically 15 to 25 percent more than Goodman
Lennox ML195 Furnace / XC15 AC series 15-16 Two-stage furnace / single-stage AC Typically 15 to 25 percent more than Goodman

Competitor rows are comparable single-stage units at similar efficiency; price is relative position, not a quote.

Questions about this system

Is 1.5 tons enough for my house, or should I size up?

A 1.5-ton system is generally appropriate for conditioned spaces in the 600-to-900 square-foot range, though the right size depends on your climate, insulation, ceiling height, and window area. Oversizing causes short-cycling, which reduces humidity control and accelerates wear, so a proper Manual J load calculation by your installer is strongly recommended before purchasing.

Can any HVAC technician service an R-32 system, or do I need a specialist?

R-32 requires EPA Section 608 certification, which most licensed HVAC technicians already hold. However, R-32 is mildly flammable, so technicians need specific training and the right recovery equipment. Availability is growing quickly, but it is worth confirming your local service providers are equipped before purchasing.

What does two-stage heating actually mean for my comfort day to day?

Two-stage means the furnace fires at a lower capacity most of the time, only stepping up to full output on the coldest days. The result is longer, gentler heating cycles that keep temperatures more stable and reduce the blasts of hot air associated with single-stage furnaces. Combined with the ECM blower, it also tends to run more quietly.

How worried should I be about the capacitor and coil issues Goodman is known for?

Capacitor failures are common across many brands, not just Goodman, and typically cost 300 to 600 dollars to repair. Evaporator coil leaks are a more serious concern because a coil replacement on an R-32 system involves refrigerant recovery by a certified technician and can cost considerably more. Budgeting for a service agreement after year five is a reasonable precaution.

Does Goodman's warranty cover both the furnace and the AC unit in this bundle?

Goodman generally offers a 10-year parts warranty on registered equipment, but coverage terms, what is included, and registration deadlines vary by component and model. You should confirm the specific warranty terms for each unit at the time of purchase and register both pieces of equipment within the required window, as unregistered units typically receive shorter coverage.

Specifications

Cooling capacity 1.5 Ton
Efficiency 15.2 SEER2
Furnace output 60000 BTU
Furnace efficiency 96% AFUE
Configuration Upflow
Refrigerant R-32
Image, specs, price and configurable options read from the AC Direct product page